What was found
SY6 CHECK, LEVEL 2 EXFOLIATION CORROSION ON SILL PLATE BETWEEN FRAME 66 - 68, AT WL-Z500, AT BL-Y1598. REPLACED SILL PLATE IAW SRM 51-72-11 & DWG D5348043.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
SY6 CHECK, LEVEL 2 EXFOLIATION CORROSION ON SILL PLATE BETWEEN FRAME 66 - 68, AT WL-Z500, AT BL-Y1598. REPLACED SILL PLATE IAW SRM 51-72-11 & DWG D5348043.