What was found
3S CHECK, 0.065 INCH CRACK INDICATION FOUND ON RT PRESSURE PLATE AT FASTENER HOLE LOCATED AT FRAME 42+17.5" & Y -1650.0 ON CTR WING BOX. R & R PRESS PLATE IAW SRM 51-72-11 & DWG D53372500.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
3S CHECK, 0.065 INCH CRACK INDICATION FOUND ON RT PRESSURE PLATE AT FASTENER HOLE LOCATED AT FRAME 42+17.5" & Y -1650.0 ON CTR WING BOX. R & R PRESS PLATE IAW SRM 51-72-11 & DWG D53372500.