What was found
AIR INTERRUPT, EMER DECLARED, LANDING UNEVENTFUL & ACFT OVERWEIGHT. DURING CLIMB CTR FUEL PRESS LOW WARNING ILLUMINATED. R & R FWD & AFT CTR TANK BOOST PUMPS, FFC REPAIR ORDER 5150405, IAW AMM 28-20-07. PERFORMED CTR FUEL PUMP LOW PRESSURE INDICATION IAW AMM 2841-00-501. CHECKED NORMAL. ACCOMPLISHED BITE CHECK OF UFI WITH NO FAULTS NOTED. EE ALSO AALA20150823001.