What was found
3S CHECK, CORROSION ON R2 DOOR CUT OUT LOWER SILL, BETWEEN FRAME 66 & 68 AT STRINGER 23R. REPLACED LOWER SILL IAW SRM 51-72-11, EA 253917 & DWG D53480009.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.