EMERGENCY LIGHT SYS FAILED FUNCTIONAL TEST AT SEATS 15ABC - 21ABC IAW MCM CARD 2908, WENT OUT BEFORE COMPLETION OF TEST. REPLACED BATTERY PACK AT M1670 IAW MM 33-51-06. OPERATIONS CHECKED NORMAL.