3S CHECK, CRACK INDICATION ON FRAME 68 COMMON TO STOP DOOR FITTING AT STRINGER 22L LEVEL AT AFT GALLEY AREA. REPAIRED FRAME IAW SRM 53-41-12 PARAGRAPH 5C & 5E FIGURE 203 & 204.