FLIGHT 803 CANNOT SHUTDOWN LT ENG WITH FUEL CUT OFF SWITCH. R & R FUEL FLOW GOVERNOR SOLENOID VLV IAW AMM 73-21-15. OPERATIONAL & LEAK CHECKED OK.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FLIGHT 803 CANNOT SHUTDOWN LT ENG WITH FUEL CUT OFF SWITCH. R & R FUEL FLOW GOVERNOR SOLENOID VLV IAW AMM 73-21-15. OPERATIONAL & LEAK CHECKED OK.