What was found
3S CHECK, SILL AT R23L IS CORRODED AT FRAME 66 + 5 INCHES. R & R SILL IAW SRM 51-72-11, 51-42-11 & DWG D53480009.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
3S CHECK, SILL AT R23L IS CORRODED AT FRAME 66 + 5 INCHES. R & R SILL IAW SRM 51-72-11, 51-42-11 & DWG D53480009.