What was found
CENTER FUEL PRESS LOW LIGHT ON PUMPS APPEAR NOT TO OPERATE. NO EMER WAS DECLARED. THE FLIGHT DIVERTED & LANDED WITHOUT FURTHER INCIDENT. ACFT WAS REMOVED FROM SERVICE. ACCOMPLISHED FAULT ISOLATION PROCEDURE & RESET UFI IAW MM 28-20-28. PERFORMED UFI OPERATIONAL TEST IAW MM 28-20-28. TEST CHECKED GOOD. CTR FUEL PUMPS OPERATIONS CHECKED GOOD, NO FURTHER FAULTS NOTED.