What was found
OXYGEN GENERATOR BAND BLACK AT ROW 30ABC, PIN OUT. REPLACED OXYGEN GENERATOR AT ROW 30ABC IAW AMM 35-22-11. OK FOR SERVICE.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
OXYGEN GENERATOR BAND BLACK AT ROW 30ABC, PIN OUT. REPLACED OXYGEN GENERATOR AT ROW 30ABC IAW AMM 35-22-11. OK FOR SERVICE.