What was found
ELECTRICAL SMOKY SMELL IN VICINITY OF 35HJ. SMELL DISSIPATED WHEN POWER PORTS WERE SHUTOFF. ACCOMPLISHED SMOKE & FUMES IN CABIN IAW AMM 05-51-50 & FIM 21-00-00-810-808. FOUND IFE SEAT AUDIO & VIDEO UNIT 31D INOPERATIVE & AUDIO & VIDEO UNITS 32D & 34F EMITTING ELEC ODORS. R & R AUDIO & VIDEO UNITS AT SEATS 31CD, 32CD & 34EFG IAW AMM 23-32-22. LOADED SOFTWARE TO SEATS, ALL SEATS INTERACTIVE. OPERATIONAL CHECKED OK ON GND. SEE ALSO AALA20151109008 & AALA20151109009.