Service difficulty report · Warning System · Airbus A319132

Difficulty date
November 9, 2015
Submitted
November 10, 2015
Operation
Air carrier
Aircraft
N827AW
Make and model
Airbus A319132
Aircraft serial
1547
Aircraft time
47,702 hours, 20,310 cycles
Part
Warning System
Condition
False Activation
Location
Cockpit
Stage of operation
TO
How discovered
O
Nature of condition
N
Precautionary procedure
C

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

MASTER WARNING ANNUNCIATED THEN WENT OFF AT ABOUT 100 KNOTS ON TAKEOFF. ABORTED THE TAKEOFF & RETURNED TO THE GATE. THE APU FIRE LOOP FAULT FLASHED AFTER THE TAKEOFF WAS REJECTED. PERFORMED BITE TEST OF THE APU FIRE & OVERHEAT DETECTION SYS IAW AMM 26-13-00-710-002-A, NO FAULTS NOTED. ACCOMPLISHED AFS GND SCAN 22-91-00-710-001-A & OPERATIONS CHECK OF THE FWS 31-50-00-710-002-A, NO FAULTS IN AIRMAN.