What was found
3S CHECK, CORROSION ON FLOORBEAM, BETWEEN FRAME 12 & 24 AT Y254. REPLACED FLOORBEAM IAW SRM 51-72-11 & DWG D53110920.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
3S CHECK, CORROSION ON FLOORBEAM, BETWEEN FRAME 12 & 24 AT Y254. REPLACED FLOORBEAM IAW SRM 51-72-11 & DWG D53110920.