AFTER STARTING APU & TURNING PACKS ON, VERY STRONG FUEL SMELL IN CABIN, DID NOT GO AWAY WITH TIME. FOUND THE APU IGV ACTUATOR LEAKING FUEL & REPLACED IT IAW MM 49-23-51. A SATISFACTORY OPERATIONAL & LEAK CHECK WAS ACCOMPLISHED.