As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
CENTER SECTION FLOOR PROXIMITY EMER LIGHTS AFT OF L2 & R2 DOOR INOPERATIVE. REFERENCE WDM 33-51-58, FOUND PUSHED BACK SOCKET ON CONNECTOR D6004P. SECURED SOCKET IAW CHAPTER 2 ON 20-72-24, OPERATIONALLY CHECKED GOOD. THE ACFT WAS NOT GNDED.