As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
ABORTED TAKEOFF & ACFT WAS GNDED. AFTER CREW APPLIED TAKEOFF POWER, THE ENGS FAILED TO PRODUCE THE REQUIRED THRUST. CREW RECEIVED MASTER CAUTION ALARM & TLA NOT IN TOGA FAULT & ABORTED THE TAKEOFF BETWEEN 90 & 100 KNOTS. THE ACFT RETURNED TO THE GATE WITH NO FURTHER INCIDENTS. ACCOMPLISHED GND POWER ASSURANCE CHECKS IAW EMM 72-00-00760-118.B WITH NO DEFECTS BEING NOTED. IT WAS DETERMINED THAT NO MECHANICAL ISSUES WITH THE ENGS & THAT THE AUTO THROTTLE SYS WAS NOT ENGAGED DURING THE TAKEOFF. ACFT WAS RETURNED TO SERVICE.