Service difficulty report · Sensor · Doug DC982

Difficulty date
January 10, 2016
Submitted
January 11, 2016
Operation
Air carrier
Aircraft
N7548A
Make and model
Doug DC982
Aircraft serial
53030
Aircraft time
70,575 hours, 36,822 cycles
Part
Sensor
Condition
Failed
Location
Cockpit
Stage of operation
CL
How discovered
O
Nature of condition
J
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

AIRCRAFT WAS GNDED. AIR INTERRUPT, EMER NOT DECLARED, LANDING UNEVENTFUL & ACFT NOT OVERWEIGHT. DURING CLIMB PRESSURIZATION FLOW CAME ON. RT PACK FLOW INDICATOR WENT TO ZERO. ACFT WOULD NOT PRESSURIZE. CABIN PRESS TRANSFER LOCKOUT & STANDBY LIGHT ON. R & R FLIGHT COMPARTMENT TEMPERATURE LIMITER SENSOR IAW AMM 21-21-61-05. PERFORMED ACFT PRESSURIZATION IAW AMM 21-32-00. OPERATIONAL CHECKED NORMAL.