Service difficulty report · Warning System · Emb ERJ190100IGW

Difficulty date
February 1, 2016
Submitted
February 4, 2016
Operation
Air carrier
Aircraft
N955UW
Make and model
Emb ERJ190100IGW
Aircraft serial
19000152
Aircraft time
17,452 hours, 14,745 cycles
Part
Warning System
Condition
False Activation
Location
Cockpit
Stage of operation
DE
How discovered
O
Nature of condition
N
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

AIRCRAFT WAS GNDED. CREW REPORTED SLAT LOCK OUT MSG ON DESCENT. DECLARED AN EMER & LANDED WITHOUT INCIDENT. PERFORMED FIM TASK 27-81-00-810-802-A. NO FAULTS FOUND, TRANSITORY CONDITION. PERFORMED FLIGHT CONTROL RETURN TO SERVICE TEST IAW AMM 27-00-00-070-801A. ACFT OK FOR CONTINUED SERVICE.