What was found
AIRCRAFT WAS NOT GNDED. RT EMER DOORS CABIN LIGHTS INOPERATIVE. REPLACED POWER SUPPLY & ACCOMPLISHED A SATISFACTORY OPERATIONAL CHECK IAW AMM 33-51-38-000-001-A & 33-51-38-401-001-A. VENDOR INSPECTED & TESTED THE UNIT CONFIRMING THE FAULT & REPLACED FUSE F2 IAW CMM 33-51-12. THE UNIT WAS REPAIRED & RETURNED AS SERVICEABLE.