What was found
FOUND CORROSION ON TOP OF FLOORBEAM AT STATION 1681, LBL 4. INSTALLED DOUBLER REPAIR IAW SRM 53-60-51-2R-3. ACFT IN BASE MX.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FOUND CORROSION ON TOP OF FLOORBEAM AT STATION 1681, LBL 4. INSTALLED DOUBLER REPAIR IAW SRM 53-60-51-2R-3. ACFT IN BASE MX.