Service difficulty report · Control Unit · Airbus A321211

Difficulty date
March 28, 2016
Submitted
March 29, 2016
Operation
Air carrier
Aircraft
N170US
Make and model
Airbus A321211
Aircraft serial
1462
Aircraft time
51,288 hours, 19,174 cycles
Part
Control Unit
Condition
False Activation
Location
Lavatory
Stage of operation
NR
How discovered
O
Nature of condition
N
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

AIRCRAFT WAS NOT GNDED. IN CRUISE WE GOT A SMOKE LAVATORY SMOKE ECAM MSG THAT LASTED FOR LESS THAN A MINUTE. NO SMOKE OR REASON FOR MSG WAS FOUND. RESET SMOKE DETECTOR CONTROL UNIT CB IAW TSM 24-00-00-818-810. OPERATIONAL CHECKED SMOKE DETECTORS IAW AMM 26-16-00-710-001A, WITH NO DEFECTS NOTED.