As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
DIVERTED, ACFT WAS GNDED. APPROX 2 MINS AFTER TAKEOFF THE ECAM SHOWED HYD GREEN RESERVOIR SYS OVERHEAT. THE FLIGHT CREW SHUTDOWN THE GREEN & BLUE HYD SYSTEMS. ACCOMPLISHED A MANUAL EXTENSION OF THE LG & DIVERTED WHERE THE ACFT LANDED SAFELY. REPLACED THE HYD POWER TRANSFER UNIT & ACCOMPLISHED A SATISFACTORY LEAK & OPERATIONAL CHECK IAW AMM 32-00-00-*860-005-A.