Service difficulty report · Smoke Detector · Airbus A330243

Difficulty date
May 31, 2016
Submitted
June 1, 2016
Operation
Air carrier
Aircraft
N292AY
Make and model
Airbus A330243
Aircraft serial
1512
Aircraft time
9,712 hours, 1,484 cycles
Part
Smoke Detector
Condition
False Activation
Location
Lavatory
Stage of operation
CR
How discovered
O
Nature of condition
N
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

SPURIOUS LAVATORY SMOKE WARNING OCCURRED INFLIGHT. NO SMOKE APPARENT IN LAVATORY. PFR INDICATES SMOKE DETECTOR UNIT FAULT. SYS TEST OF SMOKE DETECTOR CONTROL UNIT WAS ACCOMPLISHED WITH NO FAULTS NOTED. ACFT OK FOR SERVICE.