What was found
DURING CRUISE THE LEFT AC BUS OFF LIGHT ILLUMINATED 5 HOURS INTO FLIGHT. QRH RESTORED SYSTEM. LEFT AC BUS OFF LIGHT ILLUMINATED AGAIN 7 HOURS INTO FLIGHT. LEFT GENERATOR RESET THE FAILED. LEFT BUS NOT RESTOREABLE. AIRCRAFT GROUNDED. EMERGENCY DECLARED. LANDING UNEVENTFUL. MAINTENANCE ACCOMPLISHED FIM 24-20-00-810-802. INSPECTED WIRING WITH NO DEFECTS FOUND. REMOVED AND REPLACED LEFT GENERATOR CONTROL UNIT IAW AMM 24-22-02. ACCOMPLISHED ENGINE RUN IAW AMM 71-00-00-5. SYSTEM CHECKS NORMAL.