Service difficulty report · Selector Valve · Airbus A321211

Difficulty date
September 20, 2016
Submitted
September 21, 2016
Operation
Air carrier
Aircraft
N179UW
Make and model
Airbus A321211
Aircraft serial
1521
Aircraft time
52,229 hours, 19,425 cycles
Part
Selector Valve
Part number
C24703003
Part serial
H1917
Condition
Faulted
Location
Brake
Part time
51,938 hours, 19,345 cycles
Stage of operation
TO
How discovered
O
Nature of condition
J
Precautionary procedure
C

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

FLIGHT CREW REPORTED THAT ON TAKE OFF ROLL AN ECAM MESSAGE REFLECTED THAT THE PARKING BRAKE WAS ON AND THE TAKE OFF WAS ABORTED AT LESS THAN 80 KNOTS. THE AIRCRAFT RETURNED TO THE GATE. AIRCRAFT WAS GROUNDED. MAINTENANCE REPLACED PARKING BRAKE SELECTOR CONTROL VALVE 72GG PER AMM 32-45-14-400-001-A AND ACCOMPLISHED A SATISFACTORY LEAK AND OPERATIONAL CHECK.