Service difficulty report · Fire Detector · Emb ERJ190100IGW

Difficulty date
October 8, 2016
Submitted
October 11, 2016
Operation
Air carrier
Aircraft
N954UW
Make and model
Emb ERJ190100IGW
Aircraft serial
19000139
Part
Fire Detector
Part number
90480703
Part serial
423
Condition
False Indication
Location
Nr 2 Nacelle
Part time
16,601 hours, 11,507 cycles
Stage of operation
CR
How discovered
O
Nature of condition
N
Precautionary procedure
E, F, A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

ENG 2 FIRE INDICATION AT FL 300, SHUTDOWN ENG 2 AND FIRED BOTH BOTTLES. WITH ENG 2 FIRE STILL INDICATING, DECLARED AN EMERGENCY AND DIVERTED TO GSO. ENG 2 FIRE CONTINUED TO INDICATE EVEN AFTER LANDING. AFTER STOPPING ON RUNWAY, ARFF INSPECTED AIRCRAFT AND FOUND NO FIRE. SINGLE ENGINE TIME WAS 20 MINUTES. PER FIM TASK 26-11-0028UT1. REMOVED & REPLACED ENGINE 2 RT FWD FIRE DET/LOOP PER AMM 26-11-01/400. PER MOC R&R UPPER & LOWER CORE DETECTORS LOOPS PER AMM 26-11-01/400. RAN ENGINE FOR 10 MINUTES. NO FAULTS NOTED. THE AIRCRAFT WAS GROUNDED.

More about the Emb ERJ 190-100 IGW