AIRCRAFT WAS GROUNDED. DURING EMERGENCY POWER SUPPLY UNIT TEST THE 13WL ESPU FAULTED. REMOVAL AND REPLACEMENT OF ESPU NO HELP. L4 DOOR SLIDE DETERMINED TO BE CAUSE OF FAULT. REMOVED AND REPLACED SLIDE IAW AMM 25-62-44.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AIRCRAFT WAS GROUNDED. DURING EMERGENCY POWER SUPPLY UNIT TEST THE 13WL ESPU FAULTED. REMOVAL AND REPLACEMENT OF ESPU NO HELP. L4 DOOR SLIDE DETERMINED TO BE CAUSE OF FAULT. REMOVED AND REPLACED SLIDE IAW AMM 25-62-44.