FORWARD LAVATORY SMOKE DETECTOR ALARM SOUNDED DURING FLIGHT. NO SMOKE DETECTED IN LAVATORY. REMOVED AND REPLACED SMOKE DETECTOR IAW 26-14-01. OPERATIONAL CHECKED GOOD.