What was found
ON APPROACH WHEN SELECTING FLAPS TO 30 DEG. THE FLAPS DIDN’T MOVE PAST 25 DEG. WE DID A LOW APPROACH/MISSED APPROACH AND BROUGHT THE FLAPS TO ZERO. ON THE NEXT APPROACH THE FLAPS SEQUENCED CORRECTLY ALL THE WAY TO 30 DEG. LANDED NORMALLY. ACCOMPLISHED BITE OF FSEU IAW FIM TASK 27-51-00-810-801. NO FAULTS NOTED. EXTENDED AND RETRACTED FLAPS IAW AMM 27-51-00. FLAPS OPERATED NORMAL AT ALL FLAP SETTINGS. OK FOR SVC. THE AIRCRAFT WAS NOT GROUNDED.