As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
RT FUEL PUMP FAULT FOR LOW PRESSURE. FAULT ACTIVATED, AFTER 1 MINUTE WENT OFF. PUMP DID CYCLE OFF THEN ON. FUEL TEMP WAS ABNORMALLY COLD COMPARED TO OTHER TANKS. REPLACED THE NR 2 FUEL LEVEL SENSING CONTROL UNIT AS APRECAUTION IAW MM 28-46034, AND 28-46-00. OPS CHECKED GOOD.