What was found
CORROSION ON THE FLOOR SUPPORT AT RBL 32 BETWEEN BS 990 AND 992. REMOVED AND REPLACED THE FLOOR SUPPORT IAW D 51-00-05-1 AND DRAWING 147A5700.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORROSION ON THE FLOOR SUPPORT AT RBL 32 BETWEEN BS 990 AND 992. REMOVED AND REPLACED THE FLOOR SUPPORT IAW D 51-00-05-1 AND DRAWING 147A5700.