As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
DURING A WIRE EWIS CLEANING AND INSPECTION, FOUND EMERGENCY LIGHTING SYSTEM WIRES W101-01942-24 AND W101-22693-20 EXTERNAL INSULATION BROKEN AND WIRES EXPOSED AT FORWARD MAIN CABIN LEFT FUSELAGE AT STRINGER 3 AND FRAME 19. REPAIRED THE WIRES, PERFORMED SATISFACTORY OPS CHECK OF EMERGENCY EXIT LIGHTS IAW SWPM 20-41-20 AND AMM 33-50-00.