DURING A CHECK OF EMERGENCY LIGHTS, CIDS1 EMERGENCY POWER SUPPLY UNIT DISPLAYED AFT LEFT BATTERY FAULT. REPLACED THE POWER SUPPLY UNIT IAW AMM 33-51-38.