What was found
CORROSION FOUND ON LOWER SILL IN AFT GALLEY AREA BETWEEN FRAMES 66 AND 68, STRINGER 23L. REPLACED THE DOOR SILL IAW SRM 51-72-11, AND DWG D53480505.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORROSION FOUND ON LOWER SILL IN AFT GALLEY AREA BETWEEN FRAMES 66 AND 68, STRINGER 23L. REPLACED THE DOOR SILL IAW SRM 51-72-11, AND DWG D53480505.