What was found
AIRCRAFT WAS NOT GROUNDED. EMERGENCY EXIT LIGHTS BY THE R1 DOOR WILL NOT REMAIN ILLUMINATED. REMOVED AND REPLACED POWER SUPPLY M33094 PER AMM 33-51-06. OPERATIONAL CHECK GOOD.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AIRCRAFT WAS NOT GROUNDED. EMERGENCY EXIT LIGHTS BY THE R1 DOOR WILL NOT REMAIN ILLUMINATED. REMOVED AND REPLACED POWER SUPPLY M33094 PER AMM 33-51-06. OPERATIONAL CHECK GOOD.