What was found
TRAPPED WATER INDICATION ON ELEVATOR UPPER SKIN PANEL HONEYCOMB, CORE CELLS. LOCATED AT 20.5 IN. OUTBOARD FROM RIB 1 AND 7.5 IN. FROM TRAILING EDGE. REPAIRED UPPER SKIN PANEL HONEYCOMB CORE IAW SRM 55-21-11-300-005.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
TRAPPED WATER INDICATION ON ELEVATOR UPPER SKIN PANEL HONEYCOMB, CORE CELLS. LOCATED AT 20.5 IN. OUTBOARD FROM RIB 1 AND 7.5 IN. FROM TRAILING EDGE. REPAIRED UPPER SKIN PANEL HONEYCOMB CORE IAW SRM 55-21-11-300-005.