Service difficulty report · Power Supply · Airbus A330243
FAA SDR system
- Difficulty date
- December 22, 2017
- Submitted
- December 25, 2017
- Operation
- Air carrier
- Aircraft
- N279AY
- Make and model
- Airbus A330243
- Aircraft serial
- 1011
- Aircraft time
- 34,477 hours, 5,044 cycles
- Part
- Power Supply
- Part number
- 32146210
- Part serial
- 132140
- Condition
- No Test
- Location
- Emergency Lights
- Part time
- 26,708 hours, 8,911 cycles
- Stage of operation
- IN
- How discovered
- C
- Nature of condition
- L
- Precautionary procedure
- K
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
EMERGENCY LIGHTS FAILED FUNCTIONAL CHECK IAW J/C 33C20033002. REPLACED THE POWER SUPPLY IAW MM 33-57-38. AIRCRAFT WAS GROUNDED