What was found
CRACKED CABIN FLOOR SUPPORT UNDERNEATH TOP FLANGE ADJACENT TO FASTENER HOLE AT BS 294.5 PLUS 6 INCHES, BUTTLINE 0. INSTALLED A SERVICABLE FLOOR SUPPORT IAW SRM 51-40-02 AND EA 276109.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CRACKED CABIN FLOOR SUPPORT UNDERNEATH TOP FLANGE ADJACENT TO FASTENER HOLE AT BS 294.5 PLUS 6 INCHES, BUTTLINE 0. INSTALLED A SERVICABLE FLOOR SUPPORT IAW SRM 51-40-02 AND EA 276109.