CRACK FORWARD ENTRY AREA FLOOR SUPPORT BETWEEN BS 312 TO 328, LBL 47, 15 INCHES INBOARD OF DOOR ENTRY . REPLACED THE FLOOR SUPPORT IAW 51-00-05-1 AND DRAWING 141A5400.