What was found
CORROSION WAS FOUND ON FLOORBEAM AT BS 993, RBL 33 - 46. INSTALLED A NEW FLOORBEAM IAW 51-00-05-1 AND DRAWING 147A5700.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORROSION WAS FOUND ON FLOORBEAM AT BS 993, RBL 33 - 46. INSTALLED A NEW FLOORBEAM IAW 51-00-05-1 AND DRAWING 147A5700.