What was found
CORROSION FOUND ON FLOOR SUPPORT Y765 BETWEEN FRAMES 64 AND 66 IN THE AFT GALLEY AREA. REPLACED THE FLOOR SUPPORT IAW SRM 51-72-11 AND DRAWING D53472831.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORROSION FOUND ON FLOOR SUPPORT Y765 BETWEEN FRAMES 64 AND 66 IN THE AFT GALLEY AREA. REPLACED THE FLOOR SUPPORT IAW SRM 51-72-11 AND DRAWING D53472831.