What was found
CORROSION FOUND ON THE FLOOR SUPPORT -Y254, BETWEEN FRAMES 12 AND 24 AT THE FORWARD GALLEY AREA. REPLACED THE FLOOR SUPPORT IAW SRM 51-72-11, DWG D53111462, AND D53110984.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORROSION FOUND ON THE FLOOR SUPPORT -Y254, BETWEEN FRAMES 12 AND 24 AT THE FORWARD GALLEY AREA. REPLACED THE FLOOR SUPPORT IAW SRM 51-72-11, DWG D53111462, AND D53110984.