What was found
AFTER TAKEOFF, ON SELECTING THE FLAPS UP, RECEIVED ECAM , FLT CONTROL, FLAP SYSTEM 2 FAULT. ACCOMPLISHED QRH, LANDING UNEVENTFUL AT FLAPS FULL. FLAP EXTENTION SEEMED SLOWER THAN NORMAL. FLAP SYSTEM TROUBLESHOT IAW TSM 27-51-00-810-845-A. NO FAULTS FOUND. OPS TESTED THE FLAPS EXTENSION AND RETRACTION IAW AMM 27-50-00. OPS CHECKED GOOD. OK FOR SERVICE.