What was found
FLIGHT ATTENDANT REPORTED SMOKE IN THE CABIN. APU BLEED WAS TURNED OFF, SMOKE DISSIPATED. APU BLEED WAS TURNED ON AND FAULTED. AIRCRAFT WAS GROUNDED. ACCOMPLISHED APU BLEED TEST IAW TSM 36-12-00. TEST PASSED, OPS CHECKED GOOD. OPS CHECKED BOTH A/C PACKS, NO FAULTS NOTED. AIRCRAFT FOGGED DURING PACK OPERATION, NORMAL IAW TSM 21-00-00-801-804-A.