What was found
CORROSION FOUND ON THE FLOOR SUPPORT -Y465 BETWEEN FRAMES 64 AND 67+10 INCHES IN THE AFT GALLEY AREA. REPLACED THE FLOOR SUPPORT IAW SRM 51-72-11 AND DRAWING D53472816.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORROSION FOUND ON THE FLOOR SUPPORT -Y465 BETWEEN FRAMES 64 AND 67+10 INCHES IN THE AFT GALLEY AREA. REPLACED THE FLOOR SUPPORT IAW SRM 51-72-11 AND DRAWING D53472816.