What was found
CRACK INDICATION ON STRINGER 15L, FRAMES 53.5 + 2 INCHES TO 53.5A. REPLACED THE STRINGER IAW SRM 51-72-11, AND DRAWING F53370020.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CRACK INDICATION ON STRINGER 15L, FRAMES 53.5 + 2 INCHES TO 53.5A. REPLACED THE STRINGER IAW SRM 51-72-11, AND DRAWING F53370020.