What was found
CORROSION FOUND ON THE FLOOR SUPPORT, +Y765 BETWEEN FRAMES 64 TO 66 IN THE AT AFT GALLEY. REPLACED THE FLOOR SUPPORT IAW SRM 51-72-11, DRAWINGS D53472832, AND D53472815.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORROSION FOUND ON THE FLOOR SUPPORT, +Y765 BETWEEN FRAMES 64 TO 66 IN THE AT AFT GALLEY. REPLACED THE FLOOR SUPPORT IAW SRM 51-72-11, DRAWINGS D53472832, AND D53472815.