What was found
DURING AN EMERGENCY LIGHT TEST, THE EXTERIOR LOAD AFT AND INTERIOR LOAD AFT 13WLP LIGHTS FLASHING. REPLACED EMERGENCY LIGHTS 32WL, 90WL7, 90WL8, 44WL AND EMERGENCY POWER SUPPLY UNIT 13WL IAW AMM 33-51-00.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING AN EMERGENCY LIGHT TEST, THE EXTERIOR LOAD AFT AND INTERIOR LOAD AFT 13WLP LIGHTS FLASHING. REPLACED EMERGENCY LIGHTS 32WL, 90WL7, 90WL8, 44WL AND EMERGENCY POWER SUPPLY UNIT 13WL IAW AMM 33-51-00.