What was found
DELAMINATION FOUND ON FLOOR PANEL 261DF BETWEEN FRAMES 64 AND 68 IN THE AFT GALLEY AREA. REPLACED THE FLOOR PANEL IAW SRM 53-02-00, AND AMM 53-42-12.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DELAMINATION FOUND ON FLOOR PANEL 261DF BETWEEN FRAMES 64 AND 68 IN THE AFT GALLEY AREA. REPLACED THE FLOOR PANEL IAW SRM 53-02-00, AND AMM 53-42-12.