What was found
AT APPROXIMATELY 10,000 FT, TAIL COMP TEMP HIGH LIGHT ILLUMINATED. MEMORY ITEMS AND EXPANDED QRH CHECKLIST COMPLIED WITH. RETURNED TO DEPARTURE. ARFF SHOT TAIL WITH NORMAL TEMPERATURE. INSTALLED A SERVICABLE SUPPLY DUCT FOR THE RT A/C PACK BETWEEN FLOW CONTROL VALVE AND HEAT EXCHANGER IAW 21-00-00. THE AIRCRAFT WAS GROUNDED.